Stack-continuous emissions measurement and flaring data across regulated emission sources.

Permanently installed, automated monitoring of exhaust-gas and stack emissions. FUTUREGAZ supports CEMS engineering, flaring measurement, data structuring, and compliance documentation across industrial and maritime operations.

CEMS applies wherever a regulated source requires continuous, instrument-based evidence of emissions performance — as opposed to periodic testing or calculation-only approaches. The regulatory requirement determines whether CEMS is mandatory; the operational context determines the measurement basis.

CO₂ Continuous
SO₂ Sulphur emissions
NOx Stack continuous
CO Combustion
CH₄ Slip / fugitive
O₂ Reference diluent
Opacity Particulate indicator
Flow Volumetric stack
Emissions & Flaring Measurement — process flow EMISSION SOURCE SAMPLE EXTRACTION CEMS ANALYSER DAHS DATA SYSTEM REGULATORY REPORT

What this covers

MEAS-01

Measurement system design and review

Extractive versus in-situ system selection, probe positioning, sample conditioning, analyser specification, and flow measurement integration. Includes DAHS (Data Acquisition and Handling System) architecture review.

COMP-02

Compliance documentation

Structuring of continuous emissions datasets for regulatory submission. Covers data availability reporting, exceedance identification, and evidence packaging aligned to IED, EPA 40 CFR Part 75, EU ETS, and MARPOL Annex VI requirements.

QA-03

Quality assurance — QAL and calibration

EN 14181 QAL1 certification path support, QAL2 field calibration planning, QAL3 ongoing drift monitoring, and Annual Surveillance Testing (AST). Calibration traceability from certified reference materials to instrument records.

DAHS-04

DAHS data structuring and integration

Integration of raw analyser output into structured DAHS records with timestamps, quality flags, missing data substitution logic, and averaging period definitions aligned to applicable reporting requirements.

FLAR-05

Flaring measurement and reporting

Quantification of flare gas volumes and composition for regulatory reporting, carbon accounting, and operational optimisation. Covers flow measurement approaches, composition estimation, and data trail documentation.

VER-06

Emissions data verification

Independent verification of emissions datasets, calculation methodologies, and reporting outputs. Assessment of data completeness, flag logic, and audit trail integrity against applicable regulatory frameworks.

What CEMS measures — and what it does not

CEMS provides a continuous, instrument-based record of emissions at the point of measurement. It does not model, estimate, or substitute for direct measurement.

It measures

Actual stack concentrations

Real-time compound concentrations at the measurement point, averaged over defined reporting periods, with documented instrument performance and data availability.

It provides

Audit-ready data trail

A continuous, timestamped record with calibration traceability, QAL status, quality flags, and substitution methodology — structured to withstand regulatory inspection.

It does not replace

Source testing or periodic measurement

CEMS operates continuously between periodic source tests. QAL2 calibration requires periodic reference method testing; CEMS data alone does not substitute for this requirement under EN 14181.

It does not cover

Fugitive or area emissions

Stack CEMS measures point-source stack emissions. Fugitive emissions from equipment leaks, storage vessels, or area sources require separate measurement or estimation methodologies.

Industries and applications

PWR

Power generation

Gas turbines, combined cycle plants, and combustion sources regulated under EU IED or EPA 40 CFR Part 75. Continuous NOx, SO₂, CO₂, and O₂ monitoring with QAL certification.

O&G

Oil and gas

Offshore and onshore combustion sources, gas turbines, boilers, and flaring systems. Applicable to EU ETS and MARPOL Annex VI regulated operations.

CHM

Chemical and petrochemical

Process heaters, furnaces, incinerators, and complex multi-stack operations under IED permits. Data availability and exceedance management for integrated site reporting.

STE

Steel and cement

High-temperature process emissions from blast furnaces, kilns, and sinter plants. Complex multi-compound monitoring with opacity and particulate measurement.

WTE

Waste-to-energy

Municipal solid waste and clinical waste incineration under IED and Waste Incineration Directive requirements. HCl, HF, and heavy metals monitoring alongside standard stack parameters.

MAR

Maritime operations

SOx and NOx monitoring on vessels regulated under MARPOL Annex VI. Applicable to scrubber-equipped ships, ECA compliance monitoring, and port-state control requirements.

Applicable standards

EPA 40 CFR Part 75

US acid rain monitoring

Federal CEMS requirements for electricity generating units. Covers SO₂, NOx, CO₂, O₂, and volumetric flow measurement with defined QA/QC protocols and electronic reporting.

EU IED

Industrial Emissions Directive

European framework for large combustion plants and industrial installations. Defines emission limit values and continuous monitoring obligations for major point sources.

EN 14181

CEMS quality assurance

European standard for quality assurance of automated measuring systems. Defines QAL1, QAL2, QAL3, and Annual Surveillance Test requirements for IED-regulated sources.

MARPOL Annex VI

Marine air pollution

International convention limits for SOx and NOx from ship exhausts. Defines requirements for onboard continuous monitoring and emission control area (ECA) compliance.

EU ETS / MRV

Emissions trading and reporting

EU Emissions Trading System monitoring, reporting, and verification requirements. CEMS data used for verified annual emissions reports under the MRV regulation.

EN 15259

Measurement location and planning

Requirements for measurement section and measurement point siting, measurement objective, and documentation for stationary source emissions measurement.

Discuss an emissions monitoring requirement.

Describe the source type, regulated compounds, and applicable framework. We will respond with an appropriate approach.

Send an inquiry